=============================================================================== Intel(R) Server Platform Integrated BMC Firmware Release Notes =============================================================================== INTEL(R) Server Boards and Systems Intel Corporation 2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA =============================================================================== DATE: 26 September, 2014 SUBJECT: BMC firmware 01.07.6909 release notes =============================================================================== LEGAL INFORMATION =============================================================================== Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation. *Other names and brands are the property of their respective owners. Copyright (c) 2014 Intel Corporation. A portion of this firmware is open source code. The OSS source code that the customer is entitled to per OSS license has been posted on the Intel support website at the following link: http://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=21081 This open source code falls under the GPL 2.0 license, please see the license at the following link: http://www.opensource.org/licenses/gpl-2.0.php =============================================================================== ABOUT THIS RELEASE PACKAGE =============================================================================== Source file: BMC_i_0107r6909.bin Update script: BMC.nsh REVISION INFORMATION RETURNED BY GET DEVICE ID COMMAND: Operational mode: 01.07.6909 UBoot mode: . Device ID: 0x21 Manufacturer ID: 0x000157 Other version/revision information: PSU Model H/W revision FW Version 1100ADU00201 S4F (S3 HW Rev) 1.01.2F 1100ADU00201 S3 1.01.2F DPS 750XB A S4 5.**.100 *(See Note 2) DPS 750AB-5A S2 2.**.10 *(See Note 2) DPS 1200TB A 00 4.39.77 *(See Note 1) DPS 1200TB A 02 6.40.89 *(See Note 1) DPS 1200TB A S3 3.39.77 *(See Note 1) PSSF162202A 00 0.09.68 PSSF162202A S3 0.09.55 *(See Note 1) *NOTE 1: Supported but not POR. Will likely be removed in a future release. *NOTE 2: The middle version number is attached to a particular batch of power supplies and can be different for the same firmware revision. Therefore, it cannot be predicted ahead of time what it will be. Validation should ignore this value. HSBP FW: 01.10 (May be displayed as hex 1.a) Root: 01.07 WWW: 01.05 uboot: 01.04 FWPIAUPD Utility: v13.Build5 MD5 checksum of BMC_i_0107r6909.bin: e6c28d4d7f83e7450233603c894dc60a ------------------------------------------------------------------------------- =============================================================================== IMPORTANT INSTALLATION NOTES =============================================================================== The following update process must be followed to ensure a trouble free updating of your baseboard. The order is important to minimize any issues for status checking as different components are initialized. 1. BMC firmware 2. BIOS/Manageability Engine (ME) firmware (as directed in BIOS Release Notes) 3. FRU/SDR package specific to the baseboard. =============================================================================== INSTALLATION PROCEDURE =============================================================================== If upgrading from BMC FW 0.19 or older and you need the SOL fix, you need to update using a device programmer. If you already have version 0.20 or newer and you do not need the SOL fix, use the following steps. Note that when updating using a device programmer, you will lose all FRU data and will need to reprogram the default FRU data again using the FRUSDR package. 1. Copy all files to the storage medium of your choice. This can be a hard disk, floppy disk or USB flash drive. All of the files must reside in the same directory. 2. Boot to EFI and then run the BMC.nsh script file to update the Integrated BMC. Modification of the update script or using fwpiaupd.efi with your own command line parameters is not supported and doing so is at your own risk! 3. Install latest available FRU/SDR package specific to the platform. =============================================================================== FIRMWARE RECOVERY PROCEDURE =============================================================================== The Recovery process can be initiated by setting the recovery jumper (called BMC Force Update Jumper) to the recovery position. The jumper is normally in the normal/de-asserted position. The system must be completely powered off (A/C power removed) before the jumper is moved. After power is re-applied and the firmware update is complete, the system must be powered off again and the jumper must be returned to the de-asserted position before normal operation can begin. A BMC recovery can be accomplished from a USB flash drive. 1. Copy all files to a storage USB flash drive. All of the files must reside in the same directory. 2. Remove A/C power from the system and wait 30 seconds. 3. Move the BMC Force Update Jumper to the recovery position. Details regarding the jumper ID and location can be obtained from the Board EPS for that Platform. 4. Insert the USB flash drive. 5. Reapply A/C power to the system and power on the system. 6. The BIOS POST screen will appear displaying the progress press F6 to select boot options. At the boot option menu select to boot to the EFI SHELL. 7. Switch to the directory where you stored the update files and then run the BMC.nsh script file to update the Integrated BMC. Modification of the update script with your own command line parameters is not supported and doing so is at your own risk! 8. Remove A/C power from the system and wait 30 seconds. 9. Move the BMC Force Update Jumper to the normal position. 10. Reapply A/C power to the system and power on the system. NOTE: Performing this recovery procedure resets all network and user settings to defaults. The FRUSDR will also need to be reloaded after a recovery (SDR update). =============================================================================== FIRMWARE UPGRADE/DOWNGRADE PROCEDURES =============================================================================== Upgrade of BMC FW from version BMC_i_0107r6909 to later versions will be documented in the release notes for those versions. Reverting to a lower version of firmware may have unexpected side effects, including but not limited to user settings reset to defaults, and will always result in the loss of functionality which was present in the higher version but was not implemented in the lower version. We do not guarantee that any downgrade will operate without side-effects. Always observe caution when downgrading firmware. =============================================================================== KNOWN ISSUES/WORKAROUNDS/REQUIREMENTS =============================================================================== - This BMC FW update package is to be used only on PCSD server baseboards and does NOT support customer reference boards (CRB) or silicon reference platforms (SRP). Contact your Intel Representatives to determine where to download the BMC FW for these products. - The BMC FW image file in this package is to be used only with the provided FWPIAUPD update utility. Using the FW image file with a SPI flash device programmer will result in a non-functional system. =============================================================================== ISSUES FIXED =============================================================================== 01.07.6909 Production Release =============================================================================== -EPSD100244410: FIVR Fault not being detected -EPSD100244255: Some of DIMM sensors show the critical status in EWS. -EPSD100026932: Alert email page title is different to help page title on BMC Web Console -EPSD100244476: IPMB Bridging commands to satellite controllers fail -EPSD100244363: BMC Should not be logging false throttling events in the SEL when a thermal Trip event occurs -EPSD100244443: 12Gb SAS Bridgeboard Sensor 0x9E not Accessible -N/A: Update Default.SDR and FCT.sdr of S2600CW to version 1.02 -N/A: Update Default.SDR and FCT.sdr of S2600TP to version 1.01 =============================================================================== 01.06.6835 =============================================================================== -EPSD100243920: [X] BMC flash process breaks SOL session until system is rebooted -EPSD100244023: During AC power cycling test, found the BMC becomes unstable. (BMC reset) -EPSD100241497: BMC cannot be contacted until AC power cycle after restoring defaults -EPSD100243953: EWS server health page sensor reading show " Not Available" for " PS Fan Fail" sensor. -EPSD100243289: SEL show " Warning event: BMC FW Health reports SSB Temp has failed and may not be providing a valid reading." during warm cycle. -EPSD100241684: Other Unknown Events intermittently display in BWC/EWS SEL until browser is refreshed -EPSD100243818: 1100W PSU: PSU input (AC/DC) & Power Unit Redund lost events were logged to the SEL during DC cycling -EPSD100244127: LCP does not display error message or turn amber when correctable error is entered in SEL -EPSD100243954: BMC blocks front panel power button when soft power control failure happens -EPSD100244070: KVM keyboard intermittently dead after BMC cold reset. -N/A: Update 1600W Power Supply firmware to version 0.9.68 -N/A: Update S2600KP built-in SDR's to version 1.02 =============================================================================== 01.03.6776 Production Release =============================================================================== =============================================================================== REFERENCE MATERIAL =============================================================================== Common (integrated) BMC Firmware EAS (integrated) BMC Firmware Common Core EPS