============================================================================= Intel(R) Server Platform S1400FP FRU/SDR Update Release Notes ============================================================================= INTEL(R) Product Collaboration and Systems Division Intel Corporation 2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA ============================================================================= DATE: Feb 10, 2014 TO: Intel(R) Server Platform S1400FP customers SUBJECT: Integrate BMC(R) FRU/SDR update package S1400FP_FRUSDR_01.05 release notes ============================================================================= LEGAL INFORMATION ============================================================================= Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation. *Other names and brands are the property of their respective owners. Copyright (c) 2017 Intel Corporation. ============================================================================= ABOUT THIS RELEASE ============================================================================= SDR file version: 1.05 Baseboard FRU file version: 0.01 Master configuration file version: 1.05 FRUSDR UTILITY Version: 11.0 Build 20 ============================================================================= SYSTEM HARDWARE & SOFTWARE REQUIREMENTS/REVISIONS ============================================================================= - This FRU/SDR package has only been tested on S1400FP FAB1 baseboards - BMC firmware rev 01.16 (or later) MUST be preinstalled prior to installing this FRU/SDR package - BIOS R0102 or later - MB Ver Fab1 ============================================================================= IMPORTANT INSTALLATION NOTES ============================================================================= - Package and file names have changed for this version of the package. The FRU and SDR files are now named S1400FP.fru and S1400FP.sdr respectively. Also, the EFI script file name has changed to updS1400FP.nsh. ============================================================================= INSTALLATION PROCEDURE ============================================================================= 1. Ensure BMC release 01.16 or later is pre-installed before attempting this FRU/SDR update. 2. Copy all of the files in the S1400FP_FRUSDR_0105.zip archive to a USB key, hard disk drive or floppy drive. All of the files in this zip archive must reside in the same directory. 3. Boot to EFI and then run the following command to display the contents of the baseboard FRU device: FRUSDR /d FRU If device is empty(which is the case for all new FAB1 baseboards) or corrupted, then execute the following command to program the empty FRU device: For Lincoln Pass: FRUSDR /fru S1400FP.fru 4. Now execute the following command to bring up the main FRU/SDR load menu: FRUSDR /cfg master.cfg 5. Select the option which is applicable to what you want to do. On a brand new baseboard I would highly recommend to run option 3 to program both the FRU and SDR. By reprogramming the FRU you will be given the option to input data from the keyboard into various chassis, board and product areas. Ensure that you select the correct chassis from the chassis selection menu otherwise your fan sensors will not be configured properly. 6. Once the package has finished its installation, I would highly recommend to DC power off the system and cycle AC power. ============================================================================= KNOWN ISSUES/WORKAROUNDS ============================================================================= - None ============================================================================= FEATURES ADDED ============================================================================= S1400FP_FRUSDR_0105: - Add the ME sensor "PSU1 STATUS" and "PSU2 STATUS". S1400FP_FRUSDR_0104: - None. S1400FP_FRUSDR_0103: - Update settings for exit air temperature and system air flow. - Update temperature sensor(#20 #23 #24 #25 #21 #29 #2a #2b #22 #2f) normal minum setting and low critical and low non critical setting. - Update CPU1 thermal control M value. S1400FP_FRUSDR_0102: - Update Global clamp Record sensor 20h threshold to 45. - Update Global clamp Record sensor CA threshold to 0. - Update Global clamp Record sensor 5C,5D threshold to 48. - Update threshold for aggregate sensor CA in R2312 chassis SKU. - Add clamp 5C,5D to PSU domain for R2312 chassis SKU. - Update DIMM air velocity record for other chassis SKU. - Update CPU sensor MSB, LSB to 0080 in Global clamp Record tab. S1400FP_FRUSDR_0101: - Update temperature point value in Globe Stepwise Records. - Update LCC temperautre point in Globe Stepwise Records. - Update Stepwise sub-record (lower clipping curve)for chassis R2312 SKU. - Enable exist air temp and system flow rate sensor. - Update FP HEX calculate formula. - Update domain support for air flow record for chassis R2312 SKU. - Update Domain mask in system airflow formula. - Update Domain Support in Main sub record. - Update dimm clamp threshold from -8 to -4. - Add duplicate record for DIMM as B5. - ADD clamp sensor to domain 1,2. - Update PSU domain global stepwise head ID. S1400FP_FRUSDR_0100: - Modify HSBP detect fuction in Master.CFG. - Remove HSBP2 Temp sensor(Sn:0x2A) for chassis R2312 SKU. - Update Sensor-reading-unavailable Control Value for NIC sensor(SenNo: #0x2F). - Update LCC temp setting for R2312 SKU fans. FFMP_06: - Modify fan RPM for BHP. - Modify clamp rate for B0h, 20h, 23h. - Modify threshold for B0h, 25h. - Add new clamp record 64h. - Update LCC for chassis BHP fans. - Update fan normal control value to 18% for BHP Chassis. - Change CPU clamp sensor from 74 to 64 for Domain0. - Add CPU clamp sensor 64 to domain1 and domain2. - PSU Domian LCC map change in to 31 and remove UCC mapping. - Romove fan off feature for BHP chassis - Update Stepwise sub-record (upper clipping curve)for other chassis. - Delete DTS table for other chassis. - Update DIMM velocity setting for other chassis. - Update System airflow formula Record C1, C2 for UPS chassis. - Update Global Stepwise LCC for UPS. - Add Global Stepwise performance LCC for UPS. - Delete DTS table for UPS && UPS_FULL chassis. - Add performance LCC for UPS%% UPS_FULL chassis. - Update Clamp sub-record remove 21h and 25h for UPS && UPS_FULL chassis. - Update Stepwise sub-record for PS domain in UPS && UPS_FULL chassis. FFMP_05: - Modify threshold value for sensor "BB +3.0V Vbat". - Add sensor "Agg Thrm Mgn 3" for BHP Chassis. - Modify Reading Mask for sensor "Exit Air Temp" and "P1 MTT". - Add Clamp Head ID for sensor "Agg Thrm Mgn 3"(SenNo #0xCA). - Update fan fault boost value. - Update sensor clamp for domain 0 1 2. - Update Fan off PWM setting. - Update the fuction of HSBP FRU detection in Master.cfg. - Modify the fuction of chassis intrusion dection in Master.cfg. - Add auto detecting HSBP 12x3.5 fuction in Master.cfg. - Add auto detecting Storage Front Pannel in Master.cfg. - Add Sensor Front Pannel Temp for BHP chassis. - Change the tag for sensor HDD status. - Update normal control value for UPS chassis. FFMP_04: - Add Detect UPS Chassis Function in Master.cfg. - Modify the tag condition for detect Exit Air Temp sensor in Master.cfg. - Add Chassis intrustion Tag in Master.cfg. - Add System Fan 2 Sensor for UPS Chassis. - Modify sensor Tag for Chassis UPS. - Modify Sensor name for sensor 'PS1 Fan Tach1'. - Modify Sensor name for sensor 'PS2 Fan Tach1'. - Modify sensor name for HDD status. - Delete DTS Look-up table. - Add Stepwise Header ID 02. - Update Stepwise sub-record. - Update System airflow formula Record. - Update Fan sensor domain map record PS domain record. - Update fan fault value from 100% to FF to enable advancefan failure feature. - Update Advanced fan failure sub-record. - Modify auto-rearm bit for sensor Pwr Unit Redund. FFMP_03: - Add the tag for detect Exit Air Temp sensor in Master.cfg. - Modify Chassis SKU information in Master.cfg. - Modify HSBP detect fuction in Master.cfg. - Add Exit Air Temp sensor. - Modify Sensor Physical Scrty for chassis intrusion function. - Add FP NMI Diag Int sensor. - Add P1 MEM VRD Hot sensor. - Add HDD Status sensor. FFMP_02: - Update Detect CPU function in Master.cfg. - Modify Chassis SKU information in Master.cfg. - Modify tag of HDD Status Sensor. - Modify PWM value for StepWise Curve ID 8. - Modify Count of temp value pairs for StepWise Curve ID 1A. - Modify Domain Max for StepWise Curve ID 24. - Modify Domain Mask for PS domain. - Modify Record Subtype Value for Dimm Air Velocity Sensor. - Modify Domain number and sensor number for Fan sensor domain map record. - Modify Domain Mask of PS domain for Fan failure. FFMP_01: - This package is only for PO builds - Update SDR as per S1400FP_CONFIG-FSC.xls(v1.0) ============================================================================= ISSUES FIXED ============================================================================= S1400FP_FRUSDR_0105: None S1400FP_FRUSDR_0104: - Update FRUSDR utility to 11 build 20. FFMP_05: - EPSD100022322:There is not any chassis intrusion botton and header on the BHP chassis, but two events of the "Physical Scrty" sensor generated during every system boot progress. - EPSD100022282:The system status LED still remain blinking amber after stop heating Processor 1 Memory VRD Hot 0-1 sensor. FFMP_04: - EPSD100021498:The test script SleepStateInteractive_003.tlg running result was failed with FTF312. - EPSD100021486:[FW EVL]The test script AdvancedFailBoost_003.tlg running result was failed with FTF312. - EPSD100021483:[FW EVL]The test script LinearStepwise_003.tlg running result was failed with FTF312. - EPSD100021409:[System Power]PMBUS Sensor reading is fail. - EPSD100021094:[FW EVL]Power on SUT with two PSUs,plug out and plug in again a power supply's cable,then plug out another PSU's cable, only a AC lost log generated for it. FFMP_03: - EPSD100021356: There is not system airflow sensor in EWS - EPSD100021355: There is not HSC status sensor in EWS. - EPSD100021249: There is no "Processor 1 Memory VRD Hot" sensor in SDR file. - EPSD100021159: Chassis intrusion function is not avaiabled. - EPSD100021092: Generate NMI by pressing front panel NMI button,no event log for Front panel NMI generated. - EPSD100021084: After flash FRUSDR version 0.02,find all of HDD status sensor disappeared in EWS. - EPSD100021041: No event log in VRHOT# signal check test. - EPSD100020935: Only detected 3 HDDs information in SEL log with 4x3.5" backplane. - EPSD100020864: no generate a selview log during hot swap. FFMP_02: - EPSD100020921:After select the correct chassis option during update frusdr, the shown information during FURSDR updating is mismatched with te selected chassis option. - EPSD100020935: Only detected 3 HDDs information in SEL log with 4x3.5" backplane. - EPSD100020686: CPU Fan always generate some critical event log in selview after booting system every time. FFMP_01: - None ============================================================================= REFERENCE MATERIAL ============================================================================= S1400FP_CONFIG-FSC.xls(v2.3) [END OF RELEASE NOTES]